Control Board Overview
E-S 500 / 502 Classic Series Instruction Manual
5.4
!
CAUTION! Do not run 110V AC power direct to the
board. This will cause permanent damage to both
boards and void your warranty. Caution!
Gate Opener reactions to signals:
PUSH1 and Receiver (PUSH 1 terminal, PUSH 1 button, 5 Prong Receiver):
Details:
Will activate gate with momentary contact (momentary contact between PUSH1
and V+) or if you momentarily press the PUSH1 button.
• Controls both leaves in 2 leaf mode (Dip switch 2 in the ON position).
Acts as party mode control to suspend auto-reclose by activating while counting
down autoreclose in the open position.
Operational Sequence for terminal with autoclose ON (Dip switch 1 in on position):
1. In closed position - momentary contact will open gates.
2. When opening - momentary contact will stop gates and then it will auto reclose.
3. When stopped mid cycle waiting auto reclose - momentary contact will move the
gate in the direction opposite what it was moving before stopped.
4. When open and counting auto-reclose pause time - momentary contact will stop
pause time.
5. Stopped in open position from override of auto-reclose from PUSH1 or Receiver -
momentary contact will reactivate pause time and close gate.
6. When closing - momentary contact will stop the gate and then it will auto reclose.
Operational Sequence for terminal with autoclose OFF (Dip switch 1 in off position):
1. In closed position - momentary contact will open gates.
2. When opening - momentary contact will stop gates.
3. When stopped mid cycle - momentary contact will move the gate in the direction
opposite what it was moving before stopped.
4. When open - momentary contact will close gates.
5. When closing - momentary contact will stop the gate.
6. When stopped mid cycle - momentary contact will open the gate.
7. When open with auto-reclose off - momentary contact will have no effect.
8. When closing - momentary contact will re-open the gate.